COS series large volume vertical and horizontal split case pump

[PDF]VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS 1800 horizontal split case parts list power series 2 3 item number component type other qty. 2.5”1823bf 3”1824f 4”1823af 4”1823cf 4”1823df 4”1824f 8 & 69 casing assy 125# x 125# 1 179-2296-010 179-1584-010 179-1585-010 179-1585-010 179-2515-010 179-1586-010

Grundfos HS - Horizontal split case pumps Grundfos The Grundfos HS-5 Horizontal split case pump is a single stage-stage, non-self-priming, centrifugal volute pump with radial suction and radial discharge port. These pumps have a horizontal pump shaft with the impeller placed in the middle of the shaft and with self contained combination bearing housing and seal chamber on both sides of the

Vertical Split Case Pump, Vertical Water Centrifugal Pump Vertical Split Case Pumps Description: NMZV series are vertical, single stage, axially split volute casing, double suction, centrifugal pumps. It’s the vertically mounted type of NMZ series. They share the same volute casings, impellers and shafts. Comparing with the horizontal pump, vertical water pump only requires haft the floor space.

[PDF]Horizontal (and Vertical) Split Case Centrifugal Pumps cranepumps A Crane Co. Company USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598 Index - Section 29 Horizontal (and Vertical) Split Case Centrifugal Pumps Bulletin 5060A ITEM PAGES Performance Curve, Fig 5061, Size: 3 x 2 x 14, 1750, 1150 & Various RPM.

Horizontal Split Case Pump - YouTube 0:43Apr 10, 2019· Features and design features Horizontal, between the bearings, single stage, axial profile separation heart pump. Hydraulic research institute (HI) design - BB1 * High efficiency, pedal type: EVP VACUUM SOLUTION

4600 Horizontal Split Case Pumps Armstrong Fluid Technology The Armstrong 4600 horizontal split-case (HSC) double suction pumps are base mounted and engineered to substantially reduce cost over rival designs across installation, operation, and lifetime maintenance. High-efficiency NEMA-premium motors

[PDF]Split Case Pumps - Horizontally Mounted SECTION PAGE DATE A Crane Co. Company USA: (937) 778-8947 • Canada: (905) 457-6223 • International: (937) 615-3598 Split Case Pumps - Horizontally Mounted 1 1200 cranepumps Product Numbering System Bulletin 1200 11/16

Horizontal Split Case Pumps Manufacturers Suppliers These Horizontal split case pumps are of Single stage, double suction, split volute, centrifugal Non-self priming type with radial suction & discharge ports. The split case design of these pumps enables easy removal & dismantling of bearings, wearing rings, Impeller & seals without disturbing the pipeline & motor.

[PDF]Worldwide Service & Capabilities Peerless Pump Vertical Industrial and Process Pumps Vertical close coupled single stage or multi-stage turbine pumps Up to 150,000 GPM (34,091 m3/hr) Up to 2,300 Feet (701 Meters) Up to 5,000 HP (3,730 kW) Up to 450 F (232 C) B-110 Axial and Mixed Flow Pumps for Large Volume Pumping Vertical pumps for handling water in large volumes.

Horizontal Split Case - Peerless Pump offers fire pumps » 2880549 Bulletin Horizontal Centrifugal Pumps IOM » 4851938 Bulletin AE HSC Packed Repair Instrs » 4851959 Horz Split Case AE Mech Seal Pump Repair » 2883820 Repair Bulletin TU TUF-2 STGTUT TUTF-3 STG » 2883819 Bulletin TUT 4,5 Stage Pump Repair » KTR Installation Instructions

Series VSX Space Saving Double Suction Centrifugal Pumps The Bell & Gossett VSX Double-Suction Split-Case Pump has Maintenance-Free Bearings, new One-Piece Unitized Seal, Groutless Base Plate, Alignment-Friendly Coupling, reduced pump room footprint by up to 40% when compared to traditional split-case and vertical inline pumps. Using CFD technology, we can deliver identical performance in any flange configuration.

[PDF]Horizontal Split Case Centrifugal Pumps Horizontal Split Case Centrifugal Pumps 11 29 cranepumps Customer Shop Order No. Date: By: Pump Data Fig. No. Size Curve No. GPM Head Sp. Gr. Temp. Rotation Packing/Seal Motor Data MFGR Hp RPM Phase-Cycle Voltage Frame Enclosure Insulation Furnished by Mounted Fig. 5061 Pumps with Type A or B Steel Base, Coupling & Motor

Horizontal Split Case - Peerless Pump offers fire pumps » 2880549 Bulletin Horizontal Centrifugal Pumps IOM » 4851938 Bulletin AE HSC Packed Repair Instrs » 4851959 Horz Split Case AE Mech Seal Pump Repair » 2883820 Repair Bulletin TU TUF-2 STGTUT TUTF-3 STG » 2883819 Bulletin TUT 4,5 Stage Pump Repair » KTR Installation Instructions

Horizontal double suction split casing pumps - YouTube 2:15Dec 01, 2015· CHINCOPUMP is a professional of GSN series high-efficiency horizontal double suction split casing pumps manufacture. Split casing pump main advantages: 1.High efficiency and energy : Eric Chen

Volute casing pump KSB The volute casing pump is the most common type of centrifugal pump.Its characteristic feature is the volute-shaped pump casing which is typical for single-stage centrifugal pumps There are designs whose main dimensions are standardised in accordance with EN 733, EN 22858, ISO 2858 and ISO 5199, but this standardisation still leaves ample room for many design variants.

[PDF]Hydraulic Considerations in Pumping System Design • Treated effluent pumps Horizontal Split Case Characteristics • Wide flow range • Heads to ~500 ft. for single stage, higher for two-stage • High efficiency (85-95%) • Ease of maintenance • Flat curve Horizontal Vertical • Horizontal motor • Vertical motor • Single or two stage • Dual diesel / electric drive Configurations

[PDF]Practical Considerations in Pump Suction Arrangements Figure 6 is a plan view of a horizontal split case pump with several suction arrangement poor practices. They are: (1) A short-radius 90º elbow in the horizontal plane; (2) followed by a

[PDF]Centrifugal Pumps: Basic Concepts of Operation Centrifugal Pumps: Basics Concepts of Operation, Maintenance, and Troubleshooting, Part I horizontally split or axially split casing. When the split is in a vertical plane perpendicular to the rotation axis, the casing is described as either an axially or radially split case type.

Patterson Pump Company::HSC HVAC Pump EnviroFlo™ Horizontal Split Case HVAC Pumps The high-efficiency design of our HSC line of EnviroFlo™ pumps minimizes energy consumption for a more Green sustainable HVAC system. Match your pump precisely to the duty at hand in flows to 6,000 gpm and heads to 160 ft tdh.

[PDF]Typical Specifications for Horizontal Fire Pumps Peerless Pump Company Indianapolis, IN 46207-7026 HORIZONTAL SPLIT CASE FIRE PUMPS Electric Motor or Diesel Engine Driven SECTION 1520 Page 1 June 8, 2004 Typical Specifications for Horizontal Fire Pumps GENERAL: The pumps furnished for fire protection service shall be supplied with the specified drivers, controls and pump accessory

PACO Horizontal Split Case Pumps: KP Grundfos Type KPV (Vertical Split Case) The PACO KP/KPV split case pump is a single-stage, non-self-priming, between bearing, centrifugal volute pump. The axially split design allows easy removal of the top casing and access to the pump components (bearings, wear rings, impeller, and shaft seal) without disturbing the motor or pipe work.

Split Case Pumps Grundfos PACO KP / KPV. The PACO KP/KPV split case pump is a single-stage, non-self-priming, between bearing, centrifugal volute pump. The axially split design allows easy removal of the top casing and access to the pump components (bearings, wear rings, impeller, and shaft seal) without disturbing the motor or pipe work.

Water Pumps Industrial Water Pumps SPP Pumps Incorporating split case and vertical suspended bowl designs, this world class series of pumps has been developed from many of our existing well proven hydraulics. These have been finely tuned with the aid of computational fluid dynamics, with enhanced mechanical designs and innovative features.

Fire Pump Sizing and Selection - PHCP Pros Horizontal split case pumps are also called double-suction fire pumps, because the water pathways direct water to both sides of the impeller. They are the most common type of fire pump on the market, partly because of the ratings available in this style of pump